HART RTD & Thermocouple Transmitter (Ex)

Model : PR 5337

Brand: PR Electronics

  • Head mounted 2-wire transmitter with HART protocol
  • RTD input type Pt, Ni, Cu
  • Thermocouple (TC) input type B, E, J, K, L, N, R, S, T, U
  • Voltage input range: -800…+800 mV
  • 2 analog inputs and 5 device variables with status available
  • Selectable HART 5 or HART 7 protocol support
  • 1.5kVAC galvanic isolation
  • Hardware assessed for use in SIL applications
  • Ex versions for mounting in hazardous gas and dust area

Download the manuals and Get an Offer for you desired Part Number

1,800 AED Get an Offer

Catalogue
Specifications
Function

Temperature Transducer, Transmitter

Brand

PR Electronics

Number of Inputs

1

Input Type

RTD, Thermocouple

Number of Outputs

1

Output Type

DC Current

Protocol

HART

Programming

HART Protocol, PR 5909

Accuracy

< ±0.05% of span

Certification

ATEX, CSA, DNV, FM, IECEx, INMETRO, SIL2, Hardware Assessment

Power Supply

Input loop-powered

Isolation

1.5 kVAC

Operating Temperature

-40 to +85°C

Temperature Coefficient

< ±0.005% of span /°C

Protection Degree

IP 68

Dimension

Ø44×20.2 mm

Weight

50g

Other product features
Explosion Proof

No, Yes

Weight

50 g

Dimensions

90 × 75 × 45 mm

Application

  • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
  • HART communication and 4…20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
  • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
  • Amplification of bipolar mV signals to standard 4…20 mA current signals.
  • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.

Technical characteristics

  • HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
  • The HART 7 protocol offers:
    ∙ Long Tag numbers of up to 32 characters.
    ∙ Enhanced Burst Mode and Event notification with time stamping.
    ∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
    ∙ Process signal trend measurement with logs and summary data.
    ∙ Automatic event notification with time stamps.
    ∙ Command aggregation for higher communication efficiency.
  • 5337D is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
  • Continuous check of vital stored data.
  • Meeting the NAMUR NE 21 recommendations, the 5337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 5337D meets NAMUR NE43 and NE89 recommendations.

Mounting / installation

  • For DIN form B sensor head mounting.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.

Source: PR5337 Official Page

Product Documents:

Certifications:

PR Electronics Solutions:

Be the first to review “HART RTD & Thermocouple Transmitter (Ex)”

Your email address will not be published. Required fields are marked *

There are no reviews yet.

You may also like…

WhatsApp