Communication Enabler

Model : PR 4511

Brand: PR Electronics

  • Programming display for system 4000 and 9000 devices as well as selected system 3000 devices
  • Modbus RTU protocol interface over RS-485
  • Monitor process value from the built-in display
  • High 2.5 kV isolation to host unit
  • Shielded RJ45 connector on top

Download the manuals and Get an Offer for you desired Part Number

802 AED Get an Offer

Catalogue
Specifications
Function

Communications Interface

Brand

PR Electronics

Interface

RJ45 – shielded

Transmission Rate

2400 to 115200 bit/s

Certification

ATEX, EAC, FM, IECEx

Operating Temperature

-20 to +60°C

Protection Degree

IP 20

Dimension

73.2 x 23.3 x 26.5 mm

Weight

30g

Other product features
Weight

30 g

Dimensions

150 × 35 × 25 mm

Application

  • The detachable 4511 display adds Modbus RTU RS-485 serial communications to all current and future PR Electronics 4000 and 9000 units.
  • The unit converts a wide array of sensors and analog device signals measured by the PR 4000 series, like uni- and bipolar mA and voltage signals, potentiometer, Linear Resistance, RTD, and TC, to a Modbus communication line signal.
  • When mounted on a PR 9000 series, any signal coming from or going to EX classified area, like AI, AO, DI, and DO signals, can be converted to a Modbus network.
  • PR 4511 can easily and quickly configure all individual unit operating parameters using the Modbus communication or the front display menu.
  • The easily readable 4511 display can be used to read the process signal, simulate the output signal, and indicate sensor errors and internal device errors.
  • The 4511 can be moved from one device to another. The individual system 3000 / 4000 / 9000 device configuration of a transmitter can be saved and downloaded to subsequent transmitters.

Technical characteristics

  • 4511 has complete functionality for unit programming, process signal monitoring, and diagnostics handling.
  • Multidrop half-duplex connection via shielded RJ45 connector.
  • High safe galvanic isolation of 2.5 kVAC between the serial wiring and the connected system 4000 / 9000 units.
  • Modbus parameters such as station address, baud rate, stop bit(s), and parity bit are configured from the 4511 display, which also stores parameters.

Mounting / installation / programming

  • Mounting in Zone 2 / Div 2.
  • All configuration data from a PR 3000 / 4000 / 9000 device can be transferred to a PC using PR 4590.
  • A user-defined password can protect programmed parameters.
  • When mounted on devices installed upside down, a menu item allows the display to rotate 180° and the up/down buttons to switch functions.

Source: PR4511 Official Page