Universal transmitter

Model : PR 4116
  • Conversion and Isolation of standard Analog signals
  • RTD input type Pt, Ni, Cu
  • Thermocouple (TC) input type B, E, J, K, L, N, R, S, T, U
  • Potentiometer input: 10…100kΩ
  • Linear resistance input: 0…10000Ω
  • DC Current and Voltage input
  • Relay output functions: Setpoint, Window, Sensor error, Latch, Power and Off
  • DC Current and Voltage output
  • Programming and process monitoring via PR 4500 display series
  • 2.3kVAC galvanic isolation
  • FM-certified for installation in Div. 2
  • Universally powered by 21.6…253 VAC / 19.2…300 VDC

 205 Get an Offer

Specifications
Accuracy

< ±0.1% of span

Brand

PR Electronics

Certification

ATEX, Zone2, DNV, EAC, EU-RO marine, FM, Zone2 – DIV2, IECEx, Zone2, SIL2, Hardware Assessment, UL

Communication

Modbus available via PR4511/12

Dimension

109×23.5×104 mm

Function

Relay Controller, Signal Converter, Signal Isolator, Temperature Transducer, Transmitter

Input Type

DC Current, DC Voltage, Linear Resistance, Potentiometer, RTD, Thermocouple, Transmitter

Isolation Voltage

2.5 kVAC

Number of Inputs

1

Number of Outputs

1

Output Type

DC Current, DC Voltage

Power Supply

25…250VDC / 20…300VAC

Programming

4500 series devices

Temperature Coefficient

< ±0.01% of span /°C

Application
Linearized, electronic temperature measurement with RTD or TC sensor.
Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
Power supply and signal isolator for 2-wire transmitters.
Process control with 2 pairs of potential-free relay contacts and analog output.
Galvanic separation of analog signals and measurement of floating signals.
The 4116 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristics
When 4116 is used in combination with the PR 4500 display series, all operational parameters can be modified to suit any application. As the 4116 is designed with electronic hardware switches, it is not necessary to open the device for setting of DIP-switches.
A green / red front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay.
Continuous check of vital stored data for safety reasons.
4-port 2.3 kVAC galvanic isolation.
Mounting / installation / programming
Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
All programming can be password-protected.

Be the first to review “Universal transmitter”

Your email address will not be published.

There are no reviews yet.